Container house as a temporary building, because of its easy to move, beautiful and durable and better insulation effect and other characteristics, by people’s favorite, it is widely used in a variety of occasions. Container housing fire prevention is also a growing concern, here for you to introduce a few of its fire prevention skills:
Seriously implement the fire safety responsibility system, strengthen the user’s fire safety awareness, do a good job of fire safety training, improve the protection awareness; strengthen the daily fire safety management of the movable panel house, the container house is prohibited to use high-power electrical appliances, and should be promptly disconnected from all power sources when leaving the room.
Prohibit the use of open fire in the room, prohibit the container housing as a kitchen, power distribution room, flammable and explosive goods warehouse; electrical wiring must be laid in accordance with the specification requirements, all wires should be laid openly, and sets of flame-retardant tubes.
Lights and walls to maintain a safe distance. Lighting fluorescent lamps using electronic ballast type, can not use coil inductive ballast. When wires pass through color steel sandwich panel walls, they must be covered with non-flammable plastic tubes.
Each boarding house should also install qualified leakage protection device and short-circuit overload switch; when the boarding house is used as a dormitory, the doors and windows should be opened to the outside, and the beds should not be placed too densely to leave a safe passage.
Equipped with sufficient number of fire extinguishers, install indoor fire hydrant, and ensure that the water flow and pressure to meet the requirements. Adopt rock wool with good fireproof performance as the core material, which is the cure.
In the process of building, the core material should be far away from welding, gas welding and other open flame operations. In the process of use, some heat and fire sources should not be close to the steel plate, and should keep a certain distance. If you want to set up a kitchen in the color steel plate room, you need to have a temperature insulation layer, and the wall should be added with fireproof rock wool heat insulation layer.
Wires and cables should not be traversed from the core material, if they need to be traversed they should be added with protection casing, and the socket and switch box should be metal galvanized box and use the method of open installation.
Safe environment, in order to give people a happy and stable life, whether it is temporary housing, or various occasions, need a safe environment, safe life, need to pay attention to a little bit from a little bit of attention, the container housing fire is also so, safety, need to start from small things, need to start from the little things.
Post time: Dec-12-2024